- CSCD核心中文核心科技核心
- RCCSE(A+)公路运输高质量期刊T1
- Ei CompendexScopusWJCI
- EBSCOPж(AJ)JST
基于原位监测的装配式地铁车站结构拱顶接头力学性能分析
(1. 北京城建设计发展集团股份有限公司, 北京 100037; 2. 城市轨道交通绿色与安全
建造技术国家工程研究中心, 北京 100037)
网络出版日期: 2022-04-03
基金资助
国家重点研发计划(2018YFB2101002,2017YFB1201104)
Mechanical Property Analysis of Top Arch Joint for Prefabricated Underground Metro Station Structure Based on Insuit Monitoring
(1. Beijing Urban Construction Design and Development Group Co., Ltd., Beijing 100037, China;
2. National Engineering Research Center for Green & Safe Construction Technology in Urban Rail Transit, Beijing 100037, China)
Online published: 2022-04-03
林放 . 基于原位监测的装配式地铁车站结构拱顶接头力学性能分析[J]. 隧道建设, 2022 , 42(3) : 430 -436 . DOI: 10.3973/j.issn.2096-4498.2022.03.011
Top arch joints are critical in the bearing capacity of prefabricated structures. The mechanical properties of the top arch joint are investigated by analyzing the mechanical behavior of top arch joints with large bending moments during the construction period based on longterm insitu monitoring data in the Changchun metro prefabricated station. Variation trends of joint stress, relative deformation, and relative rotation angle varying with the construction progress of the top arch are discussed. Finally, the performance of top arch joints in different construction stages is analyzed and compared with numerical calculation results. The results show the following. (1) At the beginning of the top components′ assembly into a ring, the structure has a selfadaptive period and the joint stress and deformation are large. (2) After soil backfilling and waterlevel recovery, the joint′s axial force increases, and the joint′s stress and deformation decrease, positively affecting the joint′s bearing capacity. (3) The joint stress′s overall variation range is small. The two tenons of doubletenon joints rely on each other′s occlusal action to bear the external force and reflect the different properties (one pulling and one pressing) during the construction. After completing all construction stages, the doubletenon joints stabilize in a compressive stress state. (4) The top arch joint′s overall deformation is small and the safety margin is rich. The research results have practical guiding significance for prefabricated metro stations′ joint and structure design.
/
| 〈 |
|
〉 |