Experimental Study on Influence of Frost Heaving of Undercrossed Tunnel by Freezing Method with -18 ℃ Refrigerant on Upper Structure

  • WANG Lei ,
  • LI Fangzheng ,
  • FANG Liangwen ,
  • DING Hang ,
  • FU Cai
Expand
  • (1. School of Mining Construction, China Coal Research Institute, Beijing 100013, China; 2. China Coal Mine Engineering Co., Ltd., Beijing 100013, China; 3. School of Civil and Mechanical Engineering, Curtin University, Perth 6012, Australia)

Online published: 2020-10-10

摘要

在冻结下穿工程中盐水温度是影响上部结构所受冻胀压力大小的关键因素, 为了定量研究提高盐水温度对降低土体冻胀率的影响程度,基于上海地铁18号线隧道〖JP2〗冻结法下穿10号线国权路车站工程,采用试样试验和相似模拟试验方法,对-18 ℃和-28 ℃  2种冻结温度下土体产生的温度场和应力场进行研究。试样试验设计为单向封闭冻结试验,得出-18 ℃盐水较-28 ℃盐水冻结产生的冻胀压力峰值低52.9%,冻胀压力上升速度低20.1%。相似模拟试验基于相似准则对车站尺寸、冻结管路直径、盐水流量等参数进行换算,得出使用-18 ℃盐水相较-28 ℃盐水冻胀压力峰值低20%,冻胀压力上升速度低58%。整体试验结果表明: -18 ℃〖JP〗盐水冻结可以有效减小冻胀压力峰值和增长速度,且有侧向约束条件下产生的冻胀压力大于相似模拟试验中产生的冻胀压力。试验结果可以为冻胀敏感工程、有重大风险源工程提供技术参考和数据支撑。

本文引用格式

王磊 , 李方政 , 方亮文 , 丁航 , 付财 . -18 ℃盐水冻结隧道近接下穿上覆结构冻胀规律试验研究[J]. 隧道建设, 2020 , 40(9) : 1307 -1313 . DOI: 10.3973/j.issn.2096-4498.2020.09.009

Abstract

The temperature of freezing refrigerant is a key factor affecting the frost heaving force of upper structure undercrossed by tunnel. Hence, in order to quantitatively study the effect of increasing refrigerant temperature on reducing the frost heave of soil, the tunnel of Shanghai Metro Line No. 18 crossing underneath the station of Line No. 10 is taken as an example, and the temperature field and stress field of soil under the freezing temperatures of -18 ℃ and -28 ℃ are studied by laboratory experiments and similar simulation experiments. The sample test is a closed oneway freezing test, and the results show that the peak of frost heave pressure generated by the freezing of -18 ℃ refrigerant is 52.9% smaller than that of -28 ℃ refrigerant, and the rising rate of frost heave pressure is 20.1% lower. The similar simulation experiments are based on a similar law to calculate parameters such as station size, frozen pipeline diameter and the refrigerant flow, and it is concluded that the frost heave peak of -18 ℃ refrigerant is 20% lower than that of -28 ℃ refrigerant, and the raising rate of the frost heave pressure is 58% lower. The results of two groups of experiment show that the model of -18 ℃ refrigerant freezing can reduce the increasing rate and peak value of frost heave pressure effectively, and the frost heave pressure generated under lateral restraint conditions is larger than that generated in the similar simulation model test. The experimental results can provide a technical reference and data supporting for frost heaving sensitive and major risk projects.