• 中国科学引文数据库(CSCD)来源期刊
  • 中文核心期刊中文科技核心期刊
  • Scopus RCCSE中国核心学术期刊
  • 美国EBSCO数据库 俄罗斯《文摘杂志》
  • 《日本科学技术振兴机构数据库(中国)》
二维码

隧道建设(中英文) ›› 2017, Vol. 37 ›› Issue (8): 952-957.DOI: 10.3973/j.issn.1672-741X.2017.08.006

• 研究与探索 • 上一篇    下一篇

某铁路隧道内紧急救援站防灾通风方案及影响因素研究

赵东平, 蒋尧   

  1. (中铁二院工程集团有限责任公司科学技术研究院, 四川 成都 610031)
  • 收稿日期:2017-04-24 修回日期:2017-07-11 出版日期:2017-08-20 发布日期:2017-08-22
  • 作者简介:赵东平(1979—),男,黑龙江嫩江人,2008年毕业于西南交通大学,桥梁与隧道工程专业,博士,教授级高级工程师,现主要从事隧道及地下工程结构、隧道结构可靠度及隧道通风防灾等方面的设计及研究工作。Email: 704215958@qq.com。
  • 基金资助:

    中铁二院工程集团有限责任公司科研基金资助项目(KYY2016065)

Study of Fire Ventilation Scheme of Emergency Rescue Station in A Railway Tunnel and Its Influencing Factors Analysis

ZHAO Dongping, JIANG Yao   

  1. (Research Institute of Science and Technology, China Railway Eryuan Engineering Group Co., Ltd., Chengdu 610031, Sichuan, China)
  • Received:2017-04-24 Revised:2017-07-11 Online:2017-08-20 Published:2017-08-22

摘要:

为确定铁路隧道内紧急救援站防灾通风机合理的布置方案,分析相关因素对防灾通风的影响规律,合理简化防灾通风计算,以某铁路隧道内紧急救援站工程为依托,利用SES程序建立防灾通风计算模型,对风机仅布置于正洞、横通道及同时布置于正洞和横通道内3种方案进行比选,并研究自然风、火灾位置、火灾规模及隧道纵坡等因素对救援站防灾通风的单一及其综合影响规律。结果表明: 对于左右分离式隧道内紧急救援站,将风机布置于救援站前后两端的正洞内时,满足防灾通风要求的风机数量最少,是较优的布置方案; 各因素均会对防护门处风速产生影响,影响程度依次为自然风、火灾位置、火灾规模、隧道纵坡; 同时考虑自然风和火灾因素作用时,最不利工况下需要的风机数量约为不考虑其影响时的1.9倍。

关键词: 铁路隧道, 紧急救援站, 防灾通风, 自然风, 火灾规模, 火灾位置, 隧道纵坡

Abstract:

An emergency rescue station in a railway tunnel is taken as an example to study the layout scheme of jet fans, analyze the influencing factors and rationally simplify fire ventilation calculation. The fire ventilation calculation model is established by software subway environment simulation (SES); and then three fire ventilation schemes, i. e. jet fans in tunnels, those in cross passages and those in tunnels and cross passages, are compared and selected; finally, the influencing rules of natural wind, fire location, fire scale and tunnel longitudinal slope on fire ventilation are studied respectively and comprehensively. The study results show that: 1) For separated tunnels, the jet fans arranged in main tunnels in front and at end of rescue station is the best choice for minimum fan needed. 2) All the abovementioned factors have influence on wind speed at protection door; and the influencing degree of the natural wind is the largest, followed by fire location, fire scale and tunnel longitudinal slope. 3) The number of fans needed under the most unfavourable conditions of natural wind and fire conditions is 1.9 times that without consideration of influencing factor.

Key words: railway tunnel, emergency rescue station, fire ventilation, natural wind, fire scale, fire location, tunnel longitudinal slope