装配式地铁车站不同结构型式对注浆式榫槽接头的力学性能影响

林放1 2彭智勇1 2   

  1. 1. 北京城建设计发展集团股份有限公司, 北京 100037; 2. 城市轨道交通绿色与安全建造技术国家工程研究中心, 北京 100037
  • 出版日期:2022-03-20 发布日期:2022-04-03
  • 作者简介:林放(1990—),女,四川达州人,2017年毕业于西南交通大学,桥梁与隧道工程专业,博士,高级工程师,主要从事城市轨道交通工程设计研究工作。E-mail: felyo@foxmail.com。
  • 基金资助:
    国家重点研发计划(2018YFB21010022017YFB1201104)

Influence of Different Structure Types of Prefabricated Metro Station on Mechanical Properties of Grouted MortiseTenon Joint

LIN Fang1, 2, PENG Zhiyong1, 2   

  1. (1. Beijing Urban Construction Design and Development Group Co., Ltd., Beijing 100037, China; 2. National Engineering Research Center for Green & Safe Construction Technology in Urban Rail Transit, Beijing 100037, China)

  • Online:2022-03-20 Published:2022-04-03

摘要: 为研究装配式地铁车站结构型式和注浆式榫槽接头之间的力学性能影响关系,对比和分析了纯铰接接头结构、变刚度接头结构、刚性接头结构和现浇结构4种结构型式的内力和变形,并依托深圳装配式地铁车站结构方案选型,对比分析了高拱结构和坦拱结构对接头承载性能的影响。结果表明: 1)非刚性变刚度的注浆式榫槽接头对于预制构件弯矩的调幅作用明显,具有较好的变形能力。2)高拱结构的ABBC接头安全余量较坦拱结构更大,但是顶拱接头安全余量表现弱于坦拱其他接头; 考虑到所有接头都处于线性阶段,综合考虑运输和投资等因素,最终选用坦拱结构。3)利用接头承载特征曲线对坦拱结构的各个接头承载能力进行验算,结果表明,接头均满足要求,且有较大的安全余量。

关键词:

地铁车站, 预制装配, 结构型式, 注浆式榫槽接头, 接头刚度, 接头力学性能

Abstract:  The relationship between prefabricated metro station structure type and grouted mortisetenon joint performance is investigated by comparing and analyzing the internal force and deformation of four metro station structure types, i.e., pure hinged joint structure, variable stiffness joint structure, rigid joint structure, and castinplace structure. Furthermore, a comparative analysis is conducted on the influence of higharch and flatarch structures on the joints bearing performance based on the structural scheme selection of a Shenzhen prefabricated metro station. The results show the following. (1) The nonrigid grouted mortisetenon joint with variable stiffness and good deformation capacity has a noticeable amplitude modulation effect on the prefabricated components bending moment. (2) The safety margins of a higharch structures joints AB and BC are larger than that of a flatarch structure, and the top arch joints safety margin is weaker than that of flatarch structure joints. Considering that all joints are in the linear stage and the safety margin is enough, the flatarch structure is selected according to the comprehensive consideration of transportation and investment. (3) Each joints bearing capacity of the flatarch structure is evaluated using the joint bearing characteristic curve. The results prove that the joints meet the requirements, and there is still a large safety margin. 

Key words: metro station, prefabrication, structure type, grouted mortisetenon joint, joint stiffness, joint mechanical properties