Tunnel Construction ›› 2018, Vol. 38 ›› Issue (S1): 15-19.DOI: 10.3973/j.issn.2096-4498.2018.S1.003

Previous Articles     Next Articles

Study of Airtightness of Filter Cake of Paste HDN

MA Hui1, ZHU Siran2, *   

  1. (1. Guangzhou Metro, Guangzhou 510330, Guangdong, China; 2. Guangzhou Mass Transit Engineering Consultant Co., Ltd., Guangzhou 510405, Guangdong, China)
  • Received:2018-01-30 Revised:2018-05-23 Online:2018-06-15 Published:2018-06-19

Abstract:

The airtightness of filter cake of Paste HDN when opening the chamber under pressure is analyzed by laboratory test and theoretical calculation. The analytical results show that: (1) The proportion of free water in the filter cake of Paste HDNwith 3day age is about 10%. (2) Under the pressure of 0.292 MPa, 1.7% of the pore size of the filter cake of Paste HDN with 1∶2 of mudwater ratio of improved clay slurry, 1/20 of plasticizer injection amount and 3day of filming age may leak. (3) The are permeation coefficient the filter cake of Paste HDN rangesfrom 10-8 cm3/s to 10-7 cm3/s, which is 2-3 m3/h when converting to tunnel excavation crosssection with diameter of 6m; and the air compressor can fully meet the airsupply requirements.

Key words: Paste HDN, chamber opening under pressure, seepage gas volume, seepage gas coefficient, filter cake airtightness