ISSN 2096-4498

   CN 44-1745/U

二维码

Tunnel Construction ›› 2009, Vol. 29 ›› Issue (1): 57-60.DOI: B

• wenzhang • Previous Articles     Next Articles

Design of Lightweakening and Antiglare Structure at Tunnel Portal

AI Jie, YANG Baolin, LI Yuping   

  1. Gansu Provincial Communications Planning, Survey &|Design Institute Co., Ltd.
  • Received:2008-12-05 Revised:2008-12-29 Online:2009-02-20 Published:2009-11-17

Abstract:

Taking the lightweakening and antiglare design of an expressway tunnel portal in Gansu, China as an example, the authors make the comparative analysis on the operational performance of different kinds of lightweakening structures at tunnel portal. The analysis results show that lightweakening shed can not only solve the problem in the transition section of lightweakening, but also has antiglare effects. Then, the authors, by analyzing on two adverse working condition, put forward that  20°angle of incidence is the angle that induces the glare of drivers, and the points to which attention should be paid for lightweakening shed design, such as arch ribs interval, circumferential spacing of aluminium alloy pipes and luminance.

CLC Number: