There are many layout schemes of escalator and gate in
public area of metro station which can meet relevant requirements of disaster
prevention and normal service functions. Due to the same evacuation facilities
in each scheme, it is impossible to distinguish the advantages and
disadvantages of each scheme with the current calculation method of evacuation
specifications. Hence, the simulation software Pathfinder is used to simulate
and analyze each scheme and their different working conditions based on three
escalator layout schemes in public area of 12 m single column island platform.
Meanwhile, the FDS data are imported to analyze the impact of different fire
points on evacuation. From the perspective of evacuation simulation design, it
can be concluded that: (1) The layout scheme of escalator + double support +
elevator+ double support + escalator in the public area is more conducive to
passenger evacuation; (2) Attentions should be paid to the evacuation function
of vertical hinged door in paid and nonpaid areas, and the vertical
hinged door should be set on the evacuation passenger flow line.
SHI Guangyin
. Analysis of Public Area Layout of Metro Station Based on
Evacuation Simulation[J]. Tunnel Construction, 2020
, 40(9)
: 1350
-1359
.
DOI: 10.3973/j.issn.2096-4498.2020.09.014