Longitudinal connecting
flues connect the flues of the north and south line tunnels of the Qingdao 2nd
subsea tunnel. This work is the first attempt in a highway tunnel. To examine
the effect of connecting flues on the smoke exhaust of highway tunnels, various
spacings between connecting flues are set to explore the distribution patterns
of fire temperature field, smoke spread, and system resistance and determine
the optimal spacing of connecting flues. Based on the evaluation indices,
including smoke spread length and smoke exhaust efficiency, the resistance
reduction rate is proposed for the construction of an effective evaluation
model for the spacing between connecting flues. Furthermore, the configuration
forms of various spacing settings between cross passages in China are
investigated and the Fluent software is employed to simulate smoke flow
characteristics at various connecting flue spacings. The results reveal the
following: (1) The connecting flues effectively reduce the resistance of the
smoke exhaust system. (2) With shortening of the connecting flue spacing, the
smoke spreading length decreases from 260 to 180 m, the smoke exhaust
efficiency increases from 93.39% to 97.80%, and the resistance reduction rate
decreases from 15.42% to 2.20%. (3) The combined use of 750 and 1 500 m
connecting flue spacings exhibit a better smoke exhaust effect than small
spacing.
LIU Jian
. Optimization of Interval
Setting of Connecting Flues in Extra-Long Cross-Sea Highway Tunnels: A
Case Study of Qingdao 2nd Subsea Tunnel[J]. Tunnel Construction, 2024
, 44(9)
: 1874
-1882
.
DOI: 10.3973/j.issn.2096-4498.2024.09.016