ISSN 2096-4498

   CN 44-1745/U

二维码
wenzhang

Arrangement of Emergency Facilities in Tunnels under
Construction: Case Study on a Fire Disaster

Expand
  • China Railway Tunnel Group Co., Ltd

Received date: 2008-12-22

  Revised date: 2009-04-03

  Online published: 2009-09-08

Abstract

Based on a fire disaster that happened in a extralong tunnel under construction, the author analyses on the problems in the emergency rescue, and recommends a layout scheme of the emergency facilities for fire extinguishing, communications, escape, rescue as well as some requirements on emergency exit, ventilation and emergency maneuver. This paper can provide practical guidance for the preparation for fire emergency rescue in tunnels under construction. 

Cite this article

LEI Hongliang . Arrangement of Emergency Facilities in Tunnels under
Construction: Case Study on a Fire Disaster[J]. Tunnel Construction, 2009
, 29(3) : 322 -324 . DOI: B