Considering the sea water seepage, limit analysis by finite element method is used in a subsea tunnel to analyze the stability before and after grouting reinforcement. Results show that the faultrupture zone decreases the stability of tunnel. The wider the faultrupture zone is, the more unsafe the tunnel is. The more thickness the grouting loop is, the safer the tunnel is. And the faultrupture zone with slip surface of 45° tends to lose stability most. The width of subsea tunnel lining must increase, if the full seepage pressure is considered in the design of tunnel.
WANG Zai-Quan , Wang-Jian-Xin , Zheng-Ying-Ren , Zhang-Li-Meng . Analysis on Stability of Subsea Tunnel in Faultrupture Zone[J]. Tunnel Construction, 2007 , 27(增刊) : 60 -63 . DOI: A
/
| 〈 |
|
〉 |