• 中国科学引文数据库(CSCD)来源期刊
  • 中文核心期刊中文科技核心期刊
  • Scopus RCCSE中国核心学术期刊
  • 美国EBSCO数据库 俄罗斯《文摘杂志》
  • 《日本科学技术振兴机构数据库(中国)》
二维码

隧道建设(中英文) ›› 2019, Vol. 39 ›› Issue (7): 1097-1103.DOI: 10.3973/j.issn.2096-4498.2019.07.004

• 研究与探索 • 上一篇    下一篇

郑万高铁隧道口紧急救援站防灾通风方案及参数敏感性研究

赵东平1, 2, 蒋尧3, 李老三3, 杨柏洪1, 2   

  1. (1. 西南交通大学交通隧道工程教育部重点实验室, 四川成都 610031; 2. 西南交通大学土木工程学院, 四川成都 610031; 3.中铁二院工程集团有限责任公司, 四川成都 610031)
  • 收稿日期:2018-09-19 修回日期:2019-03-28 出版日期:2019-07-20 发布日期:2019-07-31
  • 作者简介:赵东平(1979—),男,黑龙江嫩江人,2008年毕业于西南交通大学,博士,教授级高级工程师,副教授,现从事隧道及地下工程结构设计、可靠度理论及通风防灾等方向的研究工作。Email: 704215958@qq.com。
  • 基金资助:

    中央高校基本科研业务费专项资金科技创新项目(2682019CX03)

Fire Ventilation Scheme and Parameter Sensitivity of Emergency Rescue Station in ZhengzhouWanzhou Highspeed Railway Tunnel Portal

ZHAO Dongping1, 2, JIANG Yao3, LI Laosan3, YANG Baihong1, 2   

  1. (1. Key Laboratory of Transportation Tunnel Engineering, Ministry of Education, Southwest Jiaotong University, Chengdu 610031, Sichuan, China; 2. School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China; 3. China Railway Eryuan Engineering Group Co., Ltd., Chengdu 610031, Sichuan, China)
  • Received:2018-09-19 Revised:2019-03-28 Online:2019-07-20 Published:2019-07-31

摘要:

为确定隧道口紧急救援站火灾工况下射流风机的最优布置方案,明确各参数对防灾通风设计方案的影响,依托郑万高铁隧道口紧急救援站工程,对火灾工况下风机的布置方案及影响因素进行研究。采用网络通风算法,研究将风机布置于正洞进口段、正洞进口段和平导进口段、正洞进口段和横通道内3种方案的优劣,以及隧道内自然风、火源位置、火灾规模及隧道纵坡等因素对正洞内及防护门处风速的影响程度及规律。研究结果表明: 1)对于隧道口紧急救援站,将风机同时布置于正洞进口段和平导进口段时需要的风机数量最少。2)隧道内自然风对隧道正洞进口段的风速影响最大,而火源位置的影响程度相对较小,火灾规模及隧道纵坡的影响规律相同;相比于隧道正洞,各因素对隧道防护门处的风速影响相对较小。3)同时考虑火灾规模、隧道纵坡、火源位置及隧道内自然风等因素时,满足防灾通风要求的风机总功率为不考虑上述因素时的2.5倍;火灾工况下,开启风机的总功率为不考虑上述因素时的3.0倍。

关键词: 高速铁路隧道, 隧道口, 紧急救援站, 防灾通风, 参数敏感性

Abstract:

The optimal layout scheme of jet fans under fire condition of emergency rescue station in tunnel portal and the influence of each parameter on the design scheme of fire ventilation are very important. Hence, based on the emergency rescue station project in ZhengzhouWanzhou Highspeed Railway Tunnel portal, the layout scheme of jet fans and its influencing factors under fire condition are studied. And then the advantages and disadvantages of 3 ventilation schemes, i.e. fans in main tunnel portal section, fans in main tunnel portal section and parallel heading portal section, and fans in main tunnel portal section and cross passage, are studied by means of network ventilation algorithm. Finally, the influence degree and rule of natural wind, fire source location, fire scale and longitudinal slope of tunnel on wind speed in the main tunnel and at the protective door are studied. The results show that: (1) The amount of jet fans needed is the smallest when the fans are arranged in the main tunnel portal section and parallel heading portal section at the same time. (2) The natural wind in the tunnel has the greatest influence on the wind speed in the main tunnel of tunnel portal section, while the fire location has a relatively small influence, and the fire scale and longitudinal slope of tunnel have the same influence degree; compared with the main tunnel, the influence of various factors on the wind speed at the protective door of tunnel is relatively small. (3) When considering the fire scale, longitudinal slope, fire source location and natural wind in the tunnel, the total power of the fan meeting the requirements of fire ventilation is 2.5 times that of the fan without consideration of the above factors. And the total power of the fan is 3.0 times that of the fan without consideration of the above factors under fire condition.

Key words: highspeed railway tunnel, tunnel portal, emergency rescue station, fire ventilation, parameter sensitivity