Shield Boring Underneath Buildings by Cutting Existing Foundation Piles: Case Study on Running Tunnel from Grand Theatre Station toLudan Village Station on Line 9 of Shenzhen Metro

SUN Bo1, XIAO Longge2, SUN Zhengyang3, YIN Minglun3, LUO Zehua4   

  1. (1. Shenzhen Metro Group Co., Ltd., Shenzhen 518026, Guangdong, China; 2. China Construction South Investment Co., Ltd., Shenzhen 518026, Guangdong,China; 3. School of Mechanics and Construction Engineering, China University of Mining and Technology, Beijing 100083, China; 4. China Construction Communications Engineering Group Ltd., Beijing 100044, China)
  • Received:2015-03-08 Revised:2015-04-10 Online:2015-06-20 Published:2015-06-25

Abstract:

In this paper, the technologies for shield boring underneath existing buildings from Grand Theater station to Ludan Village station of Shenzhen Metro is determined on basis of studying on relative technologies in China and abroad, so as to guarantee safe shield boring and avoid adverse impact on the existing pile foundations. The practicability of the construction technologies is theoretically analyzed, and the details of the construction technologies are determined. The construction technologies, including ground consolidation, trial boring, shield modification and ground surface secondary grouting, are summarized. In the end, the shield has crossed underneath the buildings successfully, and the safety of the buildings has been guaranteed.

Key words: Shenzhen Metro, shield, foundation pile cutting, nonunderpinning, boring crossing underneath buildings