Fire Characteristics and Evacuation Rescue of Double-Deck Shield Tunnel with Super-Large Cross-Section: a Case Study on Shenzhen Baoan International Airport Expressway Tunnel

SUN Ce   

  1. (Shenzhen Expressway Company Limited, Shenzhen 518038, Guangdong, China)
  • Online:2021-08-20 Published:2021-09-06

Abstract:

A Shenzhen Jihe highspeed doubledeck shield tunnel case study is being conducted to realize smoke extraction, evacuation, and rescue in a superlarge crosssection highway tunnel. Then, under varied fire conditions, the smoke extraction characteristics, temperature field, and visibility distribution at the conventional and bifurcated crosssection of the tunnel are investigated with FDS numerical simulation method. It is recommended that the longitudinal wind speed of the tunnel should be kept within 3 m/s. A comprehensive study on the emergency rescue of highway tunnel fire accidents is conducted based on the causes and characteristics of a highway tunnel fire. Furthermore, a simulation method is used to calculate six evacuation conditions in the case of multiple groups of stair parameters, and it is established that the safety evacuation requirements can be met when the crosspassage spacing is 250 m and the stair spacing is 80 m. Finally, the fire emergency rescue strategy system of the superlarge crosssection doubledeck highway tunnel is proposed, and the rescue evacuation route and smoke extraction strategy for the Jihe highspeed doubledeck shield tunnel are put forward.

Key words: highway tunnel, superlarge crosssection tunnel, fire characteristics, evacuation and rescue system, smoke extraction strategy

CLC Number: