ISSN 2096-4498

   CN 44-1745/U

二维码

Tunnel Construction ›› 2014, Vol. 34 ›› Issue (2): 173-177.DOI: 10.3973/j.issn.1672-741X.2014.02.015

Previous Articles    

Analysis on Causes for Failure of Main Drive Reducer of Shield Machine

CHANG Konglei, ZHAO Xinhe, LI Dawei   

  1. (Tunnelingdedicated Equipment Center, China Railway Tunnel Group Co., Ltd., Luoyang 471009, Henan, China)
  • Received:2013-10-24 Revised:2013-12-19 Online:2014-02-10 Published:2014-02-27

Abstract:

In this paper, the causes for the failure of the main drive reducer of shield machines are studied in terms of 〖HJ2mm〗synchronism of electric motor, disassembly of damaged reducer, break of safety axis and boring parameters of shield machine, with the shield machine for the 500 kV power tunnel in Haidian District in Beijing as an example.The main causes for the failure of the main drive reducer of the shield machine are as follows: 1) Irrational boring parameters; 2) Failure of rolling bearing of the 2nd grade and the tertiary reducers.The paper can provide reference for shield boring and reducer failure treatment in the future.

Key words: shield, main drive reducer, failure, cause analysis