The structural design of connection interface between opencut metro station and ventilation duct is discussed and analyzed in terms of structural arrangement and antifloating. The authors recommend that: 1) The arrangement of deformation seams and the design of beamcolumn system at connection interface should be strengthened and optimized and rational parameters should be adopted so as to guarantee the safety of the structure. 2) The antifloating calculation and antifloating measures should be strengthened for main structure at connection interface with high groundwater level. The relevant design of reserved interface are discussed as well.
Key words: opencut method, metro station, tnterface of ventilation duct, structural arrangement, antifloating, deformation seam, reserved interface