ISSN 2096-4498
CN 44-1745/U
Tunnel Construction ›› 2017, Vol. 37 ›› Issue (6): 717-721.DOI: 10.3973/j.issn.1672-741X.2017.06.010
Previous Articles Next Articles
ZHANG Zhigang, LIN Wei
Received:
Revised:
Online:
Published:
Abstract:
At present, the immersed tunnel of Hong KongZhuhaiMacao Link is the longest highway immersed tunnel in the world, which has active fire prevention system and passive fire prevention system. The main technical characteristics of Hong KongZhuhaiMacao Immersed Tunnel are summarized; and then the heat releasing rate, fire frequency, fireproofing rating and fireproofing standards of tunnel components are proposed. According to fire prevention conditions, fire prevention board is used for immersed tunnel segment structure; the rigid fire prevention board and flexible fire prevention board are used for immersed tunnel segment joints.
Key words: Hong KongZhuhaiMacao Link, immersed tunnel, passive fire prevention, structure fire prevention, joint fire prevention, fire prevention board
CLC Number:
U 45
ZHANG Zhigang, LIN Wei. Design of Fire Prevention for Immersed Tunnel of Hong KongZhuhaiMacao Link[J]. Tunnel Construction, 2017, 37(6): 717-721.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: http://www.suidaojs.com/EN/10.3973/j.issn.1672-741X.2017.06.010
http://www.suidaojs.com/EN/Y2017/V37/I6/717