- CSCD核心中文核心科技核心
- RCCSE(A+)公路运输高质量期刊T1
- Ei CompendexScopusWJCI
- EBSCOPж(AJ)JST

隧道建设(中英文) ›› 2023, Vol. 43 ›› Issue (7): 1099-1108.DOI: 10.3973/j.issn.2096-4498.2023.07.002
许有俊1, 2, 3, 庞跃魁1, 2, 3, *, 张朝1, 2, 3, 聂绪致1, 2, 3, 张旭1, 2, 3, 刘天宇1, 2, 3
(1. 内蒙古科技大学土木工程学院, 内蒙古 包头014010; 2. 内蒙古科技大学矿山安全与地下工程院士专家工作站, 内蒙古 包头 014010; 3. 内蒙古科技大学内蒙古自治区高校“城市地下工程技术研究中心”, 内蒙古 包头 014010)
Experimental Study on Bending Performance of an F-Type Socket Joint in Rectangular PipeJacking Tunnels
XU Youjun1, 2, 3, PANG Yuekui1, 2, 3, ZHANG Chao1, 2, 3, NIE Xuzhi1, 2, 3, ZHANG Xu1, 2, 3, LIU Tianyu1, 2, 3
(1.School of Civil Engineering,Inner Mongolia University of Science and Technology,Baotou 014010,Inner Mongolia,China;2.Academician Workstation of Mine Safety and Underground Engineering,Inner Mongolia University of Science and Technology,Baotou 014010,Inner Mongolia,China;3.Engineering Research Center of Urban Underground Engineering at Universities of Inner Mongolia Autonomous Region,Inner Mongolia University of Science and Technology,Baotou 014010,Inner Mongolia,China)
摘要: 为研究矩形顶管隧道在地基沉降及上部荷载变化等情况下F型承插接头的抗弯性能、变形规律及破坏特征,在管节底部布置不同数量的等效地基弹簧来模拟不同地质条件,开展不同地层条件下的接头弯曲试验。试验结果表明: 1)加载初期,接头弯曲变形主要为钢套环变形,各等效地基下接头抗弯刚度差异较小。2)当位移加载至15~25 mm时,管节顶底板内侧与侧墙外侧出现裂缝,由于管节自身变形使得接头张开量随着加载位移的增大出现减缓,接头抗弯刚度曲线斜率增大,并以0.007 rad张开量为界线划分为2个阶段。3)根据拉线式位移计变化、接头混凝土应变及钢套环应变可知,顶底板中部及侧墙中部挠曲应力最大,且在上方荷载作用下,管节表现出被压扁的趋势。4)接头弯曲变形中,插口端混凝土会与承口端混凝土及钢套环发生挤压,顶板混凝土被压碎,钢套环由于挤压而发生翘曲。