ISSN 2096-4498

   CN 44-1745/U

二维码

Tunnel Construction ›› 2013, Vol. 33 ›› Issue (4): 272-276.DOI: 10.3973/j.issn.1672-741X.2013.04.003

Previous Articles     Next Articles

Study on Energysaving Ventilation Technology for Multiple Tunneling Faces with Advance Parallel Gallery

ZHAO Junxi   

  1. (Technology Center of China Railway Tunnel Group Co., Ltd., Luoyang 471009, Henan, China)
  • Received:2012-12-04 Revised:2013-02-15 Online:2013-04-20 Published:2013-04-12

Abstract:

In normal cases, the ventilation for multiple tunneling faces is difficult. In the paper, comparison and contrast is made on jet flow gallery ventilation mode, main fan ventilation mode and forced ventilation mode in terms of technology and economical efficiency, with the ventilation for the entrance section of Sandu tunnel as an example. The economic rationality of the ventilation mode adopted is analyzed, the energysaving principle and energysaving effect of the automaticcontrolled frequencyconversion of the ventilation fans are analyzed theoretically. The ventilation practice demonstrates that the energysaving target has been achieved. 

Key words: parallel gallery, multiple tunneling faces, construction, ventilation, energysaving, jet flow gallery ventilation, mainfan ventilation, automaticcontrolled system