ISSN 2096-4498
CN 44-1745/U
Tunnel Construction ›› 2016, Vol. 36 ›› Issue (7): 857-861.DOI: 10.3973/j.issn.1672-741X.2016.07.014
Previous Articles Next Articles
CHEN Limin
Received:
Revised:
Online:
Published:
Abstract:
The applications of gallery ventilation technology and energy conservation heating technology to Guanjiao Tunnel (32.645 km long and twintube single line) are introduced. The intermediate separating plate is set in the inclined shaft; the space of inclined shaft top can provide space for ventilation, transportation and drainage pipelines. The ventilation distance is shortened and the air needed is guaranteed by setting transportation gallery and ventilation gallery in main tunnel. Meanwhile, energy conservation heating system is developed and good effect has been achieved.
Key words: Guanjiao Tunnel, double main tunnel gallery ventilation, energy conservation heating system, working environment
CLC Number:
U 45
CHEN Limin. Application of Gallery Ventilation Technology and Energy Conservation Heating Technology to Guanjiao Tunnel[J]. Tunnel Construction, 2016, 36(7): 857-861.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: http://www.suidaojs.com/EN/ 10.3973/j.issn.1672-741X.2016.07.014
http://www.suidaojs.com/EN/Y2016/V36/I7/857