高海拔地区隧道施工通风风量计算及风机选型研究

苟红松,李永生,罗占夫   

  1. (中铁隧道集团有限公司技术中心, 河南 洛阳 471009)
  • 收稿日期:2011-07-20 修回日期:2012-01-13 出版日期:2012-02-20 发布日期:2012-03-09
  • 作者简介:苟红松(1984—),男,四川剑阁人,2010年毕业于河南理工大学矿业工程(安全技术及工程)专业,硕士,助理工程师,现从事隧道通风科研工作。
  • 基金资助:

    铁道部科技研究开发计划项目(2007G035)

Study on Air Volume Calculation and Fan Selection for Tunneling Ventilation in Plateau Area

GOU Hongsong, LI Yongsheng, LUO Zhanfu   

  1. (Technology Center of China Railway Tunnel Group Co., Ltd., Luoyang 471009, Henan, China)
  • Received:2011-07-20 Revised:2012-01-13 Online:2012-02-20 Published:2012-03-09

摘要: 高原地区由于海拔高度的增大,空气性质及部分有害气体毒性较平原地区发生了较大变化,施工通风难度比常压下增大很多,不能以平原地区的通风技术进行简单照搬。对海拔高度与空气性质的关系,高原隧道施工通风需风量计算,高原地区通〖JP2〗风阻力变化及风机选型进行了分析。结果表明,高原地区的施工通风风量计算应考虑不同海拔高度时有害气体的体积膨胀及浓度限值,进行风机选型与通风阻力计算时应根据高原空气密度与平原地区空气密度的比值进行修正,该结论可为高原隧道施工提供借鉴和参考。

关键词: 高原, 隧道, 通风, 风机选型 

Abstract: The air quality and the toxicity of some harmful gases in plateau area are different from those in plain area. Therefore, the tunneling ventilation in plateau area is more difficult than that in plain area. The correlation between the altitude and the air quality, the calculation of the air volume needed in tunneling ventilation in plateau area, the variation in the ventilation resistance in plateau area and the fan selection in plateau area are analyzed. The study shows that the volumetric expansion and concentration limit of harmful gases at different altitudes should be considered in the calculation of the air volume needed in tunneling ventilation in plateau area and that modification should be made on the fan selection and the ventilation resistance calculation according to the ratio between the air density in plateau area and that in plain area. The paper can provide reference for tunneling in plateau area.

Key words: plateau area, tunnel, ventilation, fan selection