ISSN 2096-4498

   CN 44-1745/U

二维码

Tunnel Construction ›› 2017, Vol. 37 ›› Issue (6): 662-668.DOI: 10.3973/j.issn.1672-741X.2017.06.003

Previous Articles     Next Articles

Analysis of Interference during Infrared Water Detecting in Tunnel and Corresponding Prevention Technologies

ZHAI Qiuzhu1, LI Haibin1, WANG Yawei2   

  1. (1. Fourth Engineering Co., Ltd., China Railway 17th Bureau Group, Chongqing 401120, China; 2. Faculty of Geosciences and Environmental Engineering, Southwest Jiaotong University, Chengdu 610031, Sichuan, China)
  • Received:2016-10-24 Revised:2017-01-24 Online:2017-06-20 Published:2017-07-02

Abstract:

There are many interfering factors in infrared water detecting in tunnel, hence the detecting accuracy would be affected. The mechanism of infrared water detecting used in site test of entrance section of Xianghe Tunnel is analyzed. It is revealed that lamp and the shotcrete have significant impact on infrared water detecting results; the primary cause of the interference to infrared water detecting lies on environment temperature variation induced by the heat generated by interference sources. The main methods to prevention interference, i.e. carrying out detecting work with minimum interference source, interference temperature field establishment and detecting right along tunnel axial line and some angle between receiving hole and detecting lines, are discussed.

Key words: tunnel construction, infrared water detecting, interference sources, interference analysis, interference prevention

CLC Number: