ISSN 2096-4498

   CN 44-1745/U

二维码

Tunnel Construction ›› 2016, Vol. 36 ›› Issue (11): 1361-1365.DOI: 10.3973/j.issn.1672-741X.2016.11.012

Previous Articles     Next Articles

Discussion on Design of Drainage System of Long Underwater Tunnels

LYU Qingsong, HE Weiguo, FANG Zulei, CHENG Shihao   

  1. (China Railway Tunnel Survey & Design Institute Co., Ltd., Tianjin 300133, China)
  • Received:2016-04-19 Revised:2016-07-28 Online:2016-11-20 Published:2016-11-30

Abstract:

The problems of existing long underwater tunnels, i.e. Jiaozhou Bay Tunnel in Qingdao and Xiang’an Tunnel in Xiamen, are studied by theoretical analysis method and numerical calculation method. The designs of keys of drainage system, i.e. tunnel waterproofing, pump selection, pipe system arrangement, water hammer protection and sump volume, are analyzed. Suggestions are given as follows: 1) The water leakage of long underwater tunnel structure should be controlled strictly, and the full waterproofing method should be used. 2) The submersible pump with high corrosion resistance should be used as waste water pump. 3) The “one pipe two pumps” scheme for drainage system is the best; and there should not be more than 3 pumps in one pipe. 4) The water hammer eliminator should be used, and water hammer protection methods should be adopted as well. 5) The effective volume of sump should be decided according to risk analysis.

Key words: long underwater tunnel, drainage system, highlift submersible pump, water hammer protection, sump volume, full waterproofing method

CLC Number: